Welding risk assessment template (PDF & Excel) – pre-filled
Pre-filled risk assessment for welding, cutting and brazing with 19 typical hazards – from welding fumes and optical radiation to welding current, gas cylinders, fire and confined spaces – with measures, legal bases and inspection intervals.
As of PDF and ExcelAMS Go editorial team
Free: sign up for the newsletter once and all templates are unlocked in this browser. You can unsubscribe at any time.
Welding, cutting and brazing involve several hazards at once: welding fumes and gases, optical radiation, welding current, fire and explosion hazards from sparks and gases, as well as noise and awkward postures. The obligation to carry out a risk assessment (Gefährdungsbeurteilung) follows from Sections 5 and 6 of the Occupational Safety and Health Act (ArbSchG); for welding fumes, the Hazardous Substances Ordinance (GefStoffV) with TRGS 528 also applies, and for radiation the Ordinance on Artificial Optical Radiation (OStrV).
The template comes pre-filled with 19 typical hazards and common measures – each with its legal basis. You add the rating, owners and deadlines for your company; a second overview lists the periodic inspections, health care and instructions, with automatic due dates in Excel.
What the template contains
- Landscape PDF with 19 pre-filled hazards from welding fumes and radiation to gas cylinders and hot work
- Same structure as the general risk assessment: hazard factor, risk rating, STOP measures, deadlines, effectiveness
- Excel spreadsheet with drop-down lists and automatic risk calculation
- Overview of 9 periodic inspections, health care and instructions – in the PDF and as an Excel sheet that calculates the next due date
How to use the template
- 1
Record processes and materials
Note which processes (e.g. MAG, TIG, stick, gas welding, plasma cutting) and materials you use – unalloyed and low-alloy steel, chromium-nickel steel, aluminium, coated sheets. The amount and composition of welding fumes depend on them. Delete rows that do not apply.
- 2
Check and rate on site
Look at welding stations, extraction, gas supply and fire protection and talk to the welders. Have exposure to welding fumes determined by a competent person, for example through measurements or the methods in TRGS 528, and rate each hazard by likelihood and severity.
- 3
Follow up measures and inspections
Enter owners and deadlines, check effectiveness and keep the dates for equipment inspections, extraction, fire extinguishers, health care and instructions up to date in the second sheet. For hot work outside the workshop, also use a hot work permit.
Legal basis
- Sections 5 and 6 ArbSchG: risk assessment and documentation
- Sections 6, 7 and 14 GefStoffV with TRGS 528 (welding work) and TRGS 510: welding fumes, protective measures, instruction, gas cylinders
- Ordinance on Artificial Optical Radiation (OStrV): UV and IR radiation in arc welding
- Sections 3, 12 and 14 BetrSichV, DGUV Regulation 3 and DGUV Information 209-010 (arc welding) and 209-011 (gas welding)
- ArbMedVV Annex Part 1 and DGUV Information 205-001: health care for welding fumes, hot work permit
Frequently asked questions
What role does TRGS 528 play in the risk assessment?
TRGS 528 “Welding work” specifies the Hazardous Substances Ordinance for welding fumes and gases. It helps you estimate exposure depending on process and material and describes protective measures, from low-fume processes and extraction at the source to respiratory protection. If you comply with the TRGS, you can assume that the requirements of the GefStoffV are met in this respect.
When is occupational health care mandatory for welders?
For welding and cutting of metals, you must offer health care. A mandatory health check is required if an air concentration of 3 mg/m³ welding fume (respirable fraction) is exceeded (ArbMedVV Annex Part 1). Other triggers can be noise or carcinogenic components such as chromium(VI) and nickel compounds.
Do I need a hot work permit for welding outside the workshop?
In areas at risk of fire outside designated welding stations, yes. The permit specifies which combustibles are removed or covered, who acts as fire watch and how long checks continue after the work. DGUV Information 205-001 contains a template.
You may use and adapt the template freely in your own company and for your own clients. It reflects the regulations named as they stand.
Never search a spreadsheet for a deadline again
In AMS Go, what this template covers lives in one system with reminders, history and records at the push of a button – mobile and with AI support.
Related guides
- Risk assessment
How to do a risk assessment in Germany: a guide in 7 steps
8 minRead - Hazardous substances
Hazardous substances risk assessment in Germany: duties, TRGS 400 procedure and checklist
8 minRead - Protective measures
Respiratory protection at work in Germany: selection, health checks and rules of use
8 minRead - Protective measures
Confined space work in Germany: hazards, entry permit and rescue
8 minRead
More templates
- Work permits
Confined space entry permit template (PDF) for tanks, silos and shafts
PDFFree download - Risk assessment
Workshop risk assessment template (PDF & Excel) – pre-filled
PDF + ExcelFree download - Risk assessment
Cleaning risk assessment template (PDF & Excel) – pre-filled
PDF + ExcelFree download - Risk assessment
Metalworking risk assessment template (PDF & Excel) – pre-filled
PDF + ExcelFree download