Visual check record – template (PDF & Excel) for work equipment before use
Record for the visual check of work equipment by users before use: 28 check points for ladders, electrical devices, slings and hand tools, defect list with immediate action, weekly list for the daily check – plus an Excel check list with status.
As of PDF, Word and ExcelAMS Go editorial team
Free: sign up for the newsletter once and all templates are unlocked in this browser. You can unsubscribe at any time.
A ladder with a cracked stile, a drill with a damaged cable, a webbing sling with a cut: defects like these arise between two inspection dates and are only noticed if someone looks before use. That is why the employer must ensure that work equipment is checked for obvious defects before each use (Section 4 (5) of the German Ordinance on Industrial Safety and Health, BetrSichV). In practice this is the visual check (Sichtprüfung) by the users – for work equipment in daily use, a check every working day.
This visual check record gives the check a fixed form: check points per kind of work equipment, a defect list with immediate action and a weekly list to initial. The template does not replace the periodic inspection by a person qualified to carry out inspections (befähigte Person) under Section 14 BetrSichV – there are separate inspection reports for that, for example for ladders, electrical equipment and slings.
What the template contains
- PDF record with 28 check points in five groups: all work equipment, ladders and stepstools, electrical devices and cables, slings, hand tools
- Rating per check point with “OK”, “Defect” or “N/A” and defect list with immediate action and report
- Second page: weekly list for the daily visual check of up to 16 pieces of work equipment
- Excel sheet “Check list” with drop-down lists for kind and result and automatic status “Open” or “Done”
- Excel sheet “Check points” with all check points to adapt to your work equipment
How to use the template
- 1
Define check points and brief employees
Specify in the risk assessment which work equipment is checked before use and how, and add points from the manufacturers' manuals. In the briefing, show employees how to recognise defects and who to report them to.
- 2
Check before use
The user looks at the work equipment before use and, where necessary, tries out its function. Use page 1 for individual pieces of work equipment or spot checks and the weekly list on page 2 for work equipment in daily use.
- 3
Report defects and follow up
Work equipment with a defect that impairs safe use is taken out of use immediately, labelled and reported. Enter the defect in the Excel check list; the status stays “Open” until the date of remedy is entered.
Legal basis
- Section 4 (5) sentence 3 Ordinance on Industrial Safety and Health (BetrSichV): check of work equipment for obvious defects before each use, regular check that guards and safety devices work
- Section 4 (5) sentence 4 BetrSichV: the check is also required for work equipment for which periodic inspections are prescribed
- Section 5 (2) BetrSichV: no use of work equipment with defects that impair safe use
- Section 14 BetrSichV: periodic inspection by a person qualified to carry out inspections and recording of the results
- Section 16 (1) Occupational Safety and Health Act (ArbSchG): employees report hazards found and defects in protective systems without delay
- TRBS 1201 “Inspections and checks of work equipment and installations requiring monitoring”
Frequently asked questions
Does the visual check before use have to be documented?
The BetrSichV requires the check before each use but does not prescribe a record for it – unlike the inspections by qualified persons under Section 14 BetrSichV. A record or weekly list is useful all the same: you can show that the check is organised and takes place, and reported defects do not get lost. You decide in the risk assessment how detailed the documentation is.
Who carries out the visual check?
The employees who use the work equipment. The employer must ensure that the check is carried out (Section 4 (5) BetrSichV) – so the employer defines what is to be checked, briefs the employees on it and specifies who defects are reported to. A special qualification like that of the person qualified to carry out inspections is not required for this check.
Does the daily visual check replace the inspection by a qualified person?
No. The check before use only covers obvious defects. Work equipment exposed to influences that cause damage must also be inspected periodically by a person qualified to carry out inspections; the employer sets the intervals in the risk assessment, and the result is recorded (Section 14 (2) and (7) BetrSichV). Conversely, the check before use expressly also applies to work equipment that is inspected periodically (Section 4 (5) sentence 4 BetrSichV).
You may use and adapt the template freely in your own company and for your own clients. It reflects the regulations named as they stand.
Never search a spreadsheet for a deadline again
In AMS Go, what this template covers lives in one system with reminders, history and records at the push of a button – mobile and with AI support.
Related guides
- Inspections
Inspection intervals for work equipment in Germany: overview, duties and records
8 minRead - Testing duties
Qualified person for inspections under TRBS 1203 in Germany: requirements, duties and appointment
6 minRead - Testing duties
Ladder inspection in Germany: inspecting and using ladders and steps safely
7 minRead - Testing duties
DGUV Regulation 3: testing electrical equipment – intervals, process and records
8 minRead
More templates
- Testing duties
Work equipment inspection register template (Excel) with inspection intervals
ExcelFree download - Risk assessment
Work equipment risk assessment template (PDF & Excel) – pre-filled
PDF + ExcelFree download - Testing duties
DGUV V3 test report template (PDF) and test list (Excel)
PDF + Word + ExcelFree download - Testing duties
Ladder inspection checklist template (PDF and Excel) with ladder register
PDF + ExcelFree download