Fire extinguisher register template (PDF & Excel) with servicing dates

Excel register for all fire extinguishers with location, extinguishing agent, rating, extinguishing units and fire classes, automatically calculated next servicing and a comparison of extinguishing units per area – plus a PDF list for on-site checks.

As of PDF and ExcelAMS Go editorial team

Free: sign up for the newsletter once and all templates are unlocked in this browser. You can unsubscribe at any time.

In Germany, fire extinguishers must be serviced every two years by a competent person; the employer may only use longer intervals if the manufacturer permits them, and shorter manufacturer intervals must be observed (ASR A2.2 No. 7.4.2). The results of maintenance must be documented (No. 7.4.1) – and anyone with many extinguishers in several buildings needs an overview for this.

The Excel register records each fire extinguisher with location, extinguishing agent, rating, extinguishing units and fire classes and calculates the next servicing date automatically. A second sheet compares the existing extinguishing units per area with those required for the floor area. You take the PDF list with you on inspections.

What the template contains

  • Excel register with 18 columns from area and location through agent and extinguishing units to inspection sticker and defects
  • Automatic calculation of the next servicing (default 24 months, different manufacturer interval can be entered) with a status column
  • Drop-down lists for extinguishing agent, fire classes and extinguishing units under Table 2 of ASR A2.2
  • Second sheet: required extinguishing units per area based on floor area and comparison with the inventory
  • PDF list in landscape format with visual check for inspections and signatures

How to use the template

  1. 1

    Take stock

    Walk through all areas and enter each fire extinguisher with location, extinguishing agent, rating and fire classes. The extinguishing units follow from the rating on the device, for example 21A = 6 LE and 113B = 6 LE.

  2. 2

    Enter servicing

    Take the date of the last servicing from the inspection sticker or the servicing report. The table calculates the next servicing – if the manufacturer's interval differs, enter it as the interval.

  3. 3

    Compare areas and check

    Enter the floor area for each area in the second sheet and check whether the existing units are sufficient. During inspections, use the PDF list to check location, accessibility and sticker and pass on defects.

Fire safety in AMS GoCheck fire extinguishers during fire safety inspections in the app, record defects such as missing inspection stickers or obstructed extinguishers with photos and track them as actions with deadlines in the action plan.

Legal basis

  • ASR A2.2 No. 7.4.2: servicing of fire extinguishers every two years by competent persons, longer manufacturer intervals permitted, shorter ones binding
  • ASR A2.2 No. 7.4.1: document maintenance, servicing label on the device, repair or replace defective extinguishers without delay
  • ASR A2.2 Nos. 4.2 and 5.2 with Tables 2 and 3: extinguishing units per extinguisher and required units per floor area
  • Section 10 Occupational Safety and Health Act (ArbSchG): fire-fighting measures
  • DIN 14406-4: maintenance of portable fire extinguishers by competent persons

Frequently asked questions

How often must fire extinguishers be serviced in Germany?

Generally every two years by a competent person (ASR A2.2 No. 7.4.2). If the manufacturer permits longer intervals, you may use them; shorter manufacturer intervals must be observed. Under heavy stress, for example from weather or mobile use, shorter intervals may be necessary – and after every use the extinguisher is repaired immediately.

Do I have to keep a fire extinguisher register?

ASR A2.2 does not prescribe a specific register. It does, however, require the results of maintenance and inspection to be documented (No. 7.4.1). A register with location and servicing date is the simplest way to bundle this evidence and not miss any date.

How many extinguishing units does a fire extinguisher have?

That depends on the rating shown on the device: 13A corresponds to 4 units, 21A to 6, 27A to 9, 43A to 12 and 55A to 15; for fire class B, for example, 113B = 6 units and 233B = 15 units (ASR A2.2 Table 2). Fire classes C, D and F are not converted into units.

You may use and adapt the template freely in your own company and for your own clients. It reflects the regulations named as they stand.

Never search a spreadsheet for a deadline again

In AMS Go, what this template covers lives in one system with reminders, history and records at the push of a button – mobile and with AI support.

Contact

Get in touch

Book an appointment with us – or send us a message.

Kim Marius GräfeFrank MezlerLukas KleinBenjamin Kostrzewa

Personal and direct – with our founding team. Meet the founding team