Coffee machine, charger, drill, extension lead: almost everyone at work uses electrical devices – usually without any electrical training. To stop a crushed cable turning into an electrical accident or fire, work equipment must be checked for obvious defects before each use (Section 4(5) BetrSichV), and repairs are reserved for qualified electricians (Section 3 DGUV Regulation 3). Non-electricians learn both in the safety briefing.
The template contains a ready-made briefing for people without electrical training: electrical hazards, the visual check before every use, correct use, what non-electricians may not do, and what to do about defects, smoke and electrical accidents. A knowledge check with eight questions and an attendance list are included. The periodic testing of devices under DGUV Regulation 3 does not replace the briefing – and vice versa.
What the template contains
- PDF briefing with header details on area, person giving the briefing, type of briefing and basis
- Four topic blocks to tick off: electrical hazards, visual check, correct use, what non-electricians may not do
- Do-and-don't table and what to do about defects, smoke, electrical accidents and tripping protective devices
- Knowledge check with eight tick-box questions, answer key and attendance list with signatures
How to use the template
- 1
Adapt
Enter how defects are reported, which rules apply to private devices and who the responsible qualified electrician is. Have a device with a test sticker and, if available, a discarded defective cable ready to show.
- 2
Brief and show
Go through the topics and have participants carry out a visual check on a real device: housing, cable, plug, test sticker. Show where emergency stop switches and the fuse box are.
- 3
Check and sign
Have the knowledge check completed, discuss wrong answers and have the attendance list signed. Add reported defects and missing sockets to the action plan. Repeat at least once a year.
Knowledge check
Test your knowledge after the safety briefing. Exactly one answer per question is correct.
The check does not replace a documented safety briefing. With AMS Go you assign briefings digitally and document attendance and knowledge checks in an audit-proof way.
Legal basis
- Section 12 Occupational Safety and Health Act (ArbSchG): briefing before work starts, when things change and repeated regularly
- Sections 15 and 16 ArbSchG: use work equipment as intended, report hazards and defects without delay
- Section 4(5) Industrial Safety Ordinance (BetrSichV): check work equipment for obvious defects before each use
- Section 12 BetrSichV: briefing of employees before work equipment is used for the first time
- Section 3 DGUV Regulation 3: installation, modification and maintenance only by or under the direction and supervision of a qualified electrician
- Section 5 DGUV Regulation 3 and Section 14 BetrSichV: periodic testing of electrical equipment
Frequently asked questions
What may people without electrical training do?
Use devices as intended, check them for visible damage before every use, take defective devices out of use and report them. Repairs, modifications and work on devices or installations are reserved for qualified electricians or may only be carried out under their direction and supervision (Section 3 DGUV Regulation 3). Anyone who is to take on certain electrical tasks is trained by a qualified electrician to become an electrically instructed person.
Is the test sticker mandatory?
No. What is mandatory is the test by a qualified electrician or a person qualified to carry out tests, and its documentation (Section 5 DGUV Regulation 3, Section 14 BetrSichV). The sticker is a common aid so that employees can see during their visual check whether a device has been tested and when the next test is due.
How often must electrical devices be tested?
The employer sets the interval in the risk assessment. The implementation guidance for DGUV Regulation 3 gives a guide value of 6 months for portable devices, 3 months on construction sites; if the failure rate is below 2 percent, the interval can be extended, in offices to a maximum of 2 years. The visual check before every use applies regardless.
You may use and adapt the template freely in your own company and for your own clients. It reflects the regulations named as they stand.
Never search a spreadsheet for a deadline again
In AMS Go, what this template covers lives in one system with reminders, history and records at the push of a button – mobile and with AI support.
Related guides
- Testing duties
DGUV Regulation 3: testing electrical equipment – intervals, process and records
8 minRead - Testing duties
Electrically instructed person (EuP) and qualified electrician in Germany: who may do what?
7 minRead - Inspections
Inspection intervals for work equipment in Germany: overview, duties and records
8 minRead - Safety instruction
Safety instruction at work in Germany: duties, intervals and records
7 minRead
More templates
- Safety instruction
Ladder safety briefing template (PDF) with knowledge check and attendance list
PDFFree download - Testing duties
DGUV V3 test report template (PDF) and test list (Excel)
PDF + Word + ExcelFree download - Safety instruction
Safety instruction record template (PDF) and instruction plan (Excel)
PDF + Word + ExcelFree download - Operating instructions
Operating instructions for machinery template (PDF) under Section 12 BetrSichV
PDF + WordFree download