Fire wardens in Germany: number, duty and tasks
How many fire wardens your company needs, when 5% is not enough, what fire wardens do, how training and refreshers work and how they differ from fire safety officers and evacuation assistants.
Last updated on 8 min readAMS Go editorial team
Key points at a glance
- How many fire wardens: the number follows from the risk assessment; a share of 5% of employees is usually sufficient (ASR A2.2, point 7.3).
- More may be needed with an increased fire risk, many people present, people with reduced mobility and premises that are spread out. Shift work and absences have to be factored in.
- The fire wardens’ task is to fight incipient fires. Training combines theory with a practical extinguishing exercise (DGUV Information 205-023).
- Refreshers: ASR A2.2 cites 2 to 5 years as proven practice, DGUV Information 205-023 recommends 3 to 5 years. You set the interval on the basis of the risk assessment.
How many fire wardens does a company need?
The answer is in the Technical Rule for Workplaces ASR A2.2 “Measures against fires”, point 7.3: the number of fire wardens (Brandschutzhelfer) follows from the risk assessment. A share of 5% of employees is usually sufficient. DGUV Information 205-023, a guidance document of the German statutory accident insurance, links this figure to a normal fire risk, such as exists in office use.
Employees 10
5% calculated0.5
Guide value for fire wardens1
Employees 20
5% calculated1
Guide value for fire wardens1
Employees 50
5% calculated2.5
Guide value for fire wardens3
Employees 100
5% calculated5
Guide value for fire wardens5
Employees 250
5% calculated12.5
Guide value for fire wardens13
The table rounds up and assumes at least one person. This is a guide value for a normal fire risk, not a fixed ratio. When setting the number you must also take account of shift work and the absence of individual employees, for example due to training, holidays and illness (ASR A2.2, point 7.3(3)). In practice this means: plan so that there are enough fire wardens in the building in every shift.
Are fire wardens mandatory?
Yes. The duty follows from several rules that build on one another:
- Section 10(2) of the Occupational Safety and Health Act (Arbeitsschutzgesetz, ArbSchG): the employer names employees who take on firefighting and evacuation tasks. Their number, training and equipment must be in reasonable proportion to the number of employees and to the particular hazards.
- Section 22(2) DGUV Regulation 1: the employer familiarises a sufficient number of insured persons with the use of fire extinguishing equipment for fighting incipient fires, through instruction and practice.
- ASR A2.2, point 7.3: the Technical Rule specifies the number, the content of the instruction and the extinguishing exercise.
There is no lower limit for company size. In small companies the employer can carry out the task personally if they have the necessary training and equipment (Section 10(2) sentence 5 ArbSchG). Before naming fire wardens, the works council or staff council must be consulted.
A special rule applies on construction sites: there, the requirements for fire wardens only apply to stationary site facilities such as site offices, accommodation or workshops (ASR A2.2, point 8). Anyone carrying out work with a fire risk on site, such as welding or abrasive cutting, is instead personally instructed in theory and practice in using fire extinguishing equipment.
When 5% is not enough
ASR A2.2 and DGUV Information 205-023 name cases in which a larger number may be necessary or sensible:
Increased fire risk
What is behind itFor example where flammable substances are present, rapid fire spread or heavy smoke release is to be expected, or work such as welding, flame cutting, abrasive cutting and soldering is carried out (ASR A2.2, point 3.3)
Many people present
What is behind itSuch as visitors and other external people who do not know the building
People with reduced mobility
What is behind itThey may depend on help to leave the building
Premises that are spread out
What is behind itSeveral buildings, floors or areas far apart
Shift work and absences
What is behind itTraining, holidays, illness and staff turnover must not leave a gap
Frequently changing staff, seasonal businesses
What is behind itDGUV Information 205-023 names cinemas, hotels and restaurants as examples with particular demands on the share of trained staff and training frequency
Smaller fire extinguishers in the basic provision
What is behind itIf, with a normal fire risk, extinguishers with only 2 extinguishing agent units are counted, the number of fire wardens must, among other things, be doubled (ASR A2.2, point 5.2)
Some organisations therefore train far more employees. In its examples, ASR A2.2 cites a day-care centre for children in which all employees are trained as fire wardens.
Fire safety in AMS GoOrganise fire safety instruction for all employees and for fire wardens as well as fire safety inspections – with the Fire safety module.Tasks of fire wardens
ASR A2.2 defines fire wardens as the employees whom the employer has named for firefighting tasks in the case of incipient fires. DGUV Information 205-023 describes the aim of the training: using fire extinguishing equipment safely without endangering oneself, and making sure that employees can leave the area on their own. The training content shows what is expected of fire wardens in the event of a fire:
- raise the alarm in the event of a fire – using the company’s alarm routes and equipment
- fight incipient fires with the fire extinguishing equipment available, without endangering themselves
- make sure that employees can escape on their own
- assess the situation and know their own limits in firefighting
- where applicable, take on special tasks under Part C of the fire safety regulations (Brandschutzordnung), for example as contact person for the fire brigade
Training as a fire warden
Fire wardens must be instructed by a competent person; practical extinguishing exercises are part of this (ASR A2.2, point 7.3(4) and (5)). Content and scope are described in DGUV Information 205-023 “Fire wardens – training and qualification”.
- 1
Decide on competent trainers
Training can be given by the employer, a person the employer has assigned or an external provider, such as a fire extinguisher manufacturer, a specialist company or the fire brigade. As examples of competent people, DGUV Information 205-023 names fire safety officers with proof of examination, occupational safety specialists (Fachkräfte für Arbeitssicherheit) with corresponding fire safety training and fire brigade members who have completed the group leader course.
- 2
Teach the theory
At least 2 teaching units of 45 minutes each. Content: basics of fire safety, the company’s fire safety organisation, how fire extinguishing equipment works, hazards from fires and what to do in the event of a fire.
- 3
Carry out the practical extinguishing exercise
Handling and triggering the fire extinguishing equipment, extinguishing tactics and a realistic exercise. The duration depends on the group size; experience shows that 5 to 10 minutes of practice time per person is enough.
- 4
Brief them on their own area
Training ends with a briefing on the person’s area of responsibility in the company. If an external course does not cover company-specific knowledge, you have to provide it yourself afterwards.
- 5
Name them and make it known
You can only appoint a person once they have also been familiarised with the conditions in the company. Record the naming and make sure employees know who the fire wardens are.
Where there are company-specific features, training takes correspondingly longer in theory and practice – for example with work involving flammable substances, with extinguishing systems and wall hydrants, or where metal or fat fires are possible. Active firefighters who have completed basic firefighter training can be appointed without additional training; they too need the briefing on the company.
How often does the training have to be repeated?
There is no fixed deadline. ASR A2.2 contains a note on this: with a normal fire risk, it has proven useful in practice to repeat the instruction with exercise at intervals of 2 to 5 years. The employer sets the interval on the basis of the risk assessment. DGUV Information 205-023 recommends intervals of 3 to 5 years for refreshing knowledge.
According to DGUV Information 205-023, shorter intervals are required when there are significant changes in the company, for example:
- when the risk assessment requires it
- with new production and work processes that change the fire risk and affect the extinguishing agent, the fire extinguishing equipment or the extinguishing tactics
- when a fire warden is moved to an area where firefighting has to be approached differently
This is separate from the instruction of all employees: they are instructed on the measures against fires and what to do in the event of a fire before starting work, when their area of activity changes and then at least once a year (ASR A2.2, point 7.2).
Fire warden, fire safety officer, evacuation assistant
The three terms are often confused. They stand for different tasks:
Fire warden (Brandschutzhelfer)
TaskFight incipient fires
When needed?In principle in every company; number according to the risk assessment, usually 5% of employees
QualificationInstruction by a competent person with extinguishing exercise under DGUV Information 205-023
Fire safety officer (Brandschutzbeauftragter)
TaskAdvise and support the employer on matters of fire safety in the company
When needed?Under ASR A2.2, naming one can be appropriate with an increased fire risk; a duty can arise from other rules, in particular those of the federal states
QualificationSeparate training with a final examination under DGUV Information 205-003
Evacuation assistant (Evakuierungshelfer or Räumungshelfer)
TaskSupport people who need help, accompany visitors unfamiliar with the site to the assembly point, check areas
When needed?When the location, size and type of use of the workplace require it (DGUV Information 205-033)
QualificationThe tasks are mostly assigned in an instruction session
Are evacuation assistants mandatory? Section 10(2) ArbSchG requires employees to be named for evacuation. DGUV Information 205-033 “Alarm and evacuation” does not state a separate ratio like the one for fire wardens. It stresses that all employees are instructed on the emergency measures and should support the evacuation without endangering themselves. In many companies fire wardens also take on tasks during evacuation – who does what should then be clearly set out when they are named.
Checklist: fire wardens at work
- Fire risk classed as normal or increased in the risk assessment
- Number of fire wardens set and justified
- Shifts, sites, floors and absences taken into account
- Visitors, external people and people with reduced mobility considered
- Works council or staff council consulted before naming
- Theory and practical extinguishing exercise carried out by a competent person
- Briefing on the area of responsibility in the company completed
- Naming recorded and made known in the company
- Interval for repetition set and dates planned
- Tasks during evacuation defined
Frequently asked questions
How many fire wardens does a company with 50 employees need?
With a normal fire risk, for example in an office, 5% of employees is usually sufficient. That is 2.5 on paper, i.e. 3 fire wardens. If the company works in shifts, has several floors or has an increased fire risk, more may be needed. You set the number in the risk assessment (ASR A2.2, point 7.3).
How often does fire warden training have to be refreshed?
There is no binding deadline. According to the note in ASR A2.2, repeating it at intervals of 2 to 5 years has proven useful with a normal fire risk; DGUV Information 205-023 recommends 3 to 5 years. The employer sets the interval on the basis of the risk assessment. With significant changes in the company, it has to be repeated earlier.
Are evacuation assistants mandatory?
Section 10(2) ArbSchG obliges the employer to name employees who take on evacuation tasks. There is no fixed number for this. According to DGUV Information 205-033, there can be people with special tasks in an evacuation when the location, size and type of use of the workplace require it; the tasks are mostly assigned in an instruction session.
How do I appoint fire wardens?
ASR A2.2 and DGUV Information 205-023 do not prescribe a particular form. In writing, however, the naming can be evidenced. The person must have been trained and briefed on their area. The free template contains a collective appointment as a PDF with signature list and notice, plus an Excel overview.
Who may train fire wardens?
The employer, a person the employer has assigned or an external provider such as a fire extinguisher manufacturer, a specialist company or the fire brigade. The trainer must be competent. As examples, DGUV Information 205-023 names fire safety officers with proof of examination, occupational safety specialists with corresponding fire safety training and fire brigade members who have completed the group leader course.
This guide gives a general overview of German occupational safety law and does not replace legal advice. The regulations in force and the rules of the statutory accident insurance institutions are authoritative.
Organise occupational safety digitally
With the occupational safety software AMS Go you handle risk assessments, safety instructions, inspections and more in one system – mobile and with AI support.
Newsletter
Occupational safety, straight to your inbox
New templates, guides and changes to regulations – free from AMS Go. The newsletter is in German. You can unsubscribe at any time via the link in every email.
More guides
- First aid & fire safety
First aiders and fire wardens in Germany: how many does a company need?
7 minRead - Basics
First aiders at work in Germany: how many are mandatory?
8 minRead - Fire safety
Fire safety officer in Germany: when it is mandatory, duties and training
7 minRead - Fire safety
Evacuation drills in Germany: requirements, frequency, procedure and report
7 minRead - Fire safety
Fire extinguishers at work: calculating the number, inspection and mounting
10 minRead